<div class="sect1">\r
<h2 id="S_NoSensors">1. No sensors or only cpu usage is displayed</h2>\r
<div class="sectionbody">\r
-<div class="paragraph"><p>Psensor is relying on few libraries or softwares for retrieving the information about the computer:</p></div>\r
+<div class="paragraph"><p>Psensor is relying on few libraries or softwares for retrieving the\r
+information about the computer:</p></div>\r
<div class="ulist"><ul>\r
<li>\r
<p>\r
</li>\r
</ul></div>\r
</li>\r
+</ul></div>\r
+<div class="paragraph"><p>For hard disk drives, psensor can use:</p></div>\r
+<div class="ulist"><ul>\r
+<li>\r
+<p>\r
+udisks2: added since 1.1.2 release. It is the default and\r
+ recommended provider.\r
+</p>\r
+</li>\r
+<li>\r
+<p>\r
+hddtemp: verify that it is correctly reporting temperature by\r
+ using the command: <code>sudo hddtemp /dev/sda</code>. It is the default\r
+ provider until 1.1.2 release.\r
+</p>\r
+</li>\r
<li>\r
<p>\r
-HDDs: it uses the hddtemp daemon. Verify that it is\r
- correctly reporting temperature by using the command: <code>sudo\r
- hddtemp /dev/sda</code>. If hddtemp does not support your disk,\r
- you may want to try using the libatasmart support instead\r
- (option <code>--use-libatasmart</code>).\r
+atasmart library: before the 1.1.2 release it can be enabled\r
+ by using the command line option <code>--use-libatasmart</code>.\r
</p>\r
</li>\r
</ul></div>\r
report it. Otherwise, the issue is on the underlying software itself\r
and you should contact the corresponding development team or refer to\r
its documentation.</p></div>\r
+<div class="paragraph"><p>Since the release 1.1.2, the providers can be enabled or disabled directly\r
+from the user interface (<code>Preferences>Provider</code>).</p></div>\r
</div>\r
</div>\r
<div class="sect1">\r
</div>\r
</div>\r
<div class="sect1">\r
-<h2 id="S_disk">16. How to monitor the temperature of a disk?</h2>\r
+<h2 id="S_disk">16. How to monitor the temperature of a disk with <code>hddtemp</code>?</h2>\r
<div class="sectionbody">\r
-<div class="paragraph"><p>By default, Psensor is using <code>hddtemp</code> to retrieve the temperature of\r
-the disks.</p></div>\r
+<div class="paragraph"><p>Until the release 1.1.2, Psensor is using <code>hddtemp</code> by default to\r
+retrieve the temperature of the disks.</p></div>\r
<div class="paragraph"><p>If <code>hddtemp</code> is installed but no disk temperature is reported, check\r
that the daemon is running by using for example the command <code>ps\r
-eaf|grep hddtemp</code>.\r